{"product_id":"pompe-a-chaleur-kit-pac-air-eau-haier-hydro-all-in-one-r290-12-kw-monophasee-avec-ballon-ecs-integre-de-200-l","title":"Heat pump: Haier Hydro All-In-One R290 12 kW single-phase air\/water PAC kit with integrated 200 L hot water tank","description":"\u003cdiv style=\"font-family: Arial, Helvetica, sans-serif; color: #333333; line-height: 1.6; max-width: 1100px; margin: 0 auto;\"\u003e\n\n\n  \u003cdiv style=\"background-color: #f4f7f5; padding: 24px; border-left: 5px solid #4d8b5b; margin-bottom: 25px;\"\u003e\n\n    \u003cp style=\"font-size: 18px; margin: 0 0 10px 0;\"\u003e\n      \u003cstrong\u003eComplete Haier Hydro All-In-One R290 12 kW single-phase air\/water heat pump package with integrated 200 L domestic hot water tank\u003c\/strong\u003e, designed to provide heating, cooling, and domestic hot water in a compact, high-performance solution.\n    \u003c\/p\u003e\n\n    \u003cp style=\"margin: 0;\"\u003e\n      This Haier solution combines a \u003cstrong\u003e12 kW R290 outdoor unit\u003c\/strong\u003e with an \u003cstrong\u003eAll-In-One indoor unit that directly incorporates a 200-litre domestic hot water tank\u003c\/strong\u003e, as well as the main hydraulic components required for the system to operate.\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eAn all-in-one solution for heating and domestic hot water\u003c\/h2\u003e\n\n\n  \u003cp\u003e\n    The \u003cstrong\u003eHaier Hydro All-In-One R290 12 kW\u003c\/strong\u003e is an air\/water heat pump designed to meet the heating and domestic hot water needs of residential buildings.\n  \u003c\/p\u003e\n\n\n  \u003cp\u003e\n    Its \u003cstrong\u003eHydro All-In-One\u003c\/strong\u003e design combines the \u003cstrong\u003eAW122HVGHA\u003c\/strong\u003e outdoor unit with the \u003cstrong\u003eHU162F20AHYA\u003c\/strong\u003e indoor unit. The latter incorporates a \u003cstrong\u003e200-litre domestic hot water tank\u003c\/strong\u003e as well as several hydraulic components, allowing the essential functions to be grouped in a single indoor column. The AW122HVGHA + HU162F20AHYA combination is officially listed by Haier and certified for heating and domestic hot water production.\n  \u003c\/p\u003e\n\n\n  \u003cp\u003e\n    The system uses the \u003cstrong\u003enatural R290 refrigerant\u003c\/strong\u003e and features Inverter technology, allowing the heat pump's operation to be adapted to the building's needs.\n  \u003c\/p\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eKey features of the Haier Hydro All-In-One 12 kW\u003c\/h2\u003e\n\n\n  \u003cul\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003e12 kW nominal heating capacity\u003c\/strong\u003e at 7 °C outdoor temperature and 35 °C water temperature\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003e200-litre domestic hot water tank integrated\u003c\/strong\u003e into the indoor unit\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eHydro All-In-One technology\u003c\/strong\u003e for a compact installation\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eR290 refrigerant\u003c\/strong\u003e, natural and with very low global warming potential\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eInverter technology\u003c\/strong\u003e to adapt the power to the needs\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eEnergy class A+++\u003c\/strong\u003e at 35 °C and 55 °C\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eCOP of 5.10\u003c\/strong\u003e at 7 °C outdoor \/ 35 °C water\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eCOP of 3.30\u003c\/strong\u003e at 7 °C outdoor \/ 55 °C water\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eSCOP of 4.82\u003c\/strong\u003e at low temperature and \u003cstrong\u003e3.85\u003c\/strong\u003e at medium temperature\u003c\/li\u003e\n\n    \u003cli\u003eWater flow temperature up to \u003cstrong\u003e80 °C\u003c\/strong\u003e\n\n\u003c\/li\u003e\n\n    \u003cli\u003eHeating operation down to \u003cstrong\u003e-25 °C\u003c\/strong\u003e outdoor temperature\u003c\/li\u003e\n\n    \u003cli\u003e\u003cstrong\u003e220-240 V \/ 50 Hz single-phase power supply\u003c\/strong\u003e\u003c\/li\u003e\n\n    \u003cli\u003eReversible operation with \u003cstrong\u003eheating and cooling\u003c\/strong\u003e\n\n\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eTwo-zone control\u003c\/strong\u003e and climate curve management\u003c\/li\u003e\n\n  \u003c\/ul\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eHydro All-In-One R290 technology\u003c\/h2\u003e\n\n\n  \u003cp\u003e\n    The \u003cstrong\u003eAll-In-One\u003c\/strong\u003e design groups several hydraulic and sanitary functions in the indoor unit. Haier indicates, in particular, that the \u003cstrong\u003eexpansion vessel, flow sensor, and pump\u003c\/strong\u003e are integrated into the All-In-One unit.\n  \u003c\/p\u003e\n\n\n  \u003cp\u003e\n    This design helps limit the number of separately installed pieces of equipment and maintains a compact installation. The indoor unit also features an integrated wiring centre to facilitate electrical connection, and the connection to the outdoor unit is made with a 2-wire cable.\n  \u003c\/p\u003e\n\n\n  \u003cdiv style=\"background-color: #f4f7f5; padding: 20px; margin: 25px 0;\"\u003e\n\n    \u003cp style=\"margin: 0;\"\u003e\n      \u003cstrong\u003eKey point:\u003c\/strong\u003e the 200-litre domestic hot water tank is directly integrated into the \u003cstrong\u003eHU162F20AHYA\u003c\/strong\u003e indoor unit. It is therefore not a separate water heater that needs to be installed separately.\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eHeating performance\u003c\/h2\u003e\n\n\n  \u003cdiv style=\"background-color: #f8f9fa; padding: 20px; margin: 20px 0;\"\u003e\n\n    \u003cp\u003e\u003cstrong\u003eHeating capacity at 7 °C outdoor \/ 35 °C water:\u003c\/strong\u003e 12.00 kW\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003ePower consumption at 7 °C \/ 35 °C water:\u003c\/strong\u003e 2.35 kW\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eCOP at 7 °C \/ 35 °C water:\u003c\/strong\u003e 5.10\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eHeating capacity at 7 °C outdoor \/ 55 °C water:\u003c\/strong\u003e 11.50 kW\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003ePower consumption at 7 °C \/ 55 °C water:\u003c\/strong\u003e 3.48 kW\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eCOP at 7 °C \/ 55 °C water:\u003c\/strong\u003e 3.30\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eSCOP at 35 °C:\u003c\/strong\u003e 4.82\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eSCOP at 55 °C:\u003c\/strong\u003e 3.85\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eEnergy class:\u003c\/strong\u003e A+++ at 35 °C \/ A+++ at 55 °C\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R290\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003ePower supply:\u003c\/strong\u003e 220-240 V \/ 50 Hz single-phase\u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n\n  \u003cp style=\"font-size: 13px; color: #666666;\"\u003e\n    The COP and SCOP values correspond to the manufacturer's standardised test conditions. Actual performance may vary depending on the outdoor temperature, water flow temperature, sizing, and operating conditions. The manufacturer's data is confirmed by the HP KEYMARK certification of the AW122HVGHA + HU162F20AHYA combination.\n  \u003c\/p\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eHaier AW122HVGHA outdoor unit\u003c\/h2\u003e\n\n\n  \u003cp\u003e\n    The \u003cstrong\u003eAW122HVGHA\u003c\/strong\u003e outdoor unit recovers the heat present in the outdoor air and transfers it to the system's hydraulic circuit.\n  \u003c\/p\u003e\n\n\n  \u003cul\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eModel:\u003c\/strong\u003e AW122HVGHA\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eHeating capacity:\u003c\/strong\u003e 12 kW at A7\/W35\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eHeating capacity at A7\/W55:\u003c\/strong\u003e 11.5 kW\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eTechnology:\u003c\/strong\u003e DC Inverter\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eCompressor:\u003c\/strong\u003e DC Inverter Twin Rotary\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R290\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e 220-240 V \/ 50 Hz single-phase\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eHeating operating range:\u003c\/strong\u003e -25 to +35 °C\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eCooling operating range:\u003c\/strong\u003e 10 to +48 °C\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eDomestic hot water operating range:\u003c\/strong\u003e -25 to +43 °C\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eHydraulic connections:\u003c\/strong\u003e R1 \/ R1\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eNet dimensions:\u003c\/strong\u003e 1250 × 460 × 880 mm (L × D × H)\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eNet weight:\u003c\/strong\u003e approximately 111 kg\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eAcoustic power:\u003c\/strong\u003e 63 dB(A) under A7\/W35 conditions\u003c\/li\u003e\n\n  \u003c\/ul\u003e\n\n\n  \u003cp\u003e\n    The HP KEYMARK certification indicates an acoustic power level of \u003cstrong\u003e63 dB(A)\u003c\/strong\u003e at low temperature and \u003cstrong\u003e66 dB(A)\u003c\/strong\u003e at medium temperature for the outdoor unit.\n  \u003c\/p\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eHaier HU162F20AHYA indoor unit\u003c\/h2\u003e\n\n\n  \u003cp\u003e\n    The \u003cstrong\u003eHU162F20AHYA\u003c\/strong\u003e indoor unit forms the hydraulic and sanitary heart of the system. It directly incorporates the \u003cstrong\u003e200-litre\u003c\/strong\u003e domestic hot water tank.\n  \u003c\/p\u003e\n\n\n  \u003cul\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eModel:\u003c\/strong\u003e HU162F20AHYA\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eType:\u003c\/strong\u003e Hydro All-In-One indoor unit\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eIntegrated domestic hot water tank:\u003c\/strong\u003e 200 litres\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e 220-240 V \/ 50 Hz\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eIntegrated expansion vessel:\u003c\/strong\u003e 8 L\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eCirculation pump:\u003c\/strong\u003e integrated\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eFlow sensor:\u003c\/strong\u003e integrated\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eHeating connections:\u003c\/strong\u003e R1 \/ R1\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eDomestic hot water connections:\u003c\/strong\u003e R3\/4\"\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eNet dimensions:\u003c\/strong\u003e 590 × 590 × 1780 mm (L × D × H)\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eNet weight:\u003c\/strong\u003e approximately 116.5 kg\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eAcoustic power:\u003c\/strong\u003e 42 dB(A)\u003c\/li\u003e\n\n  \u003c\/ul\u003e\n\n\n  \u003cp\u003e\n    The Haier documentation confirms the dimensions of 1780 × 590 × 595 mm, a net weight of 116.5 kg, and an acoustic power level of 42 dB(A) for the indoor unit of the 12\/14\/16 kW single-phase range.\n  \u003c\/p\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eIntegrated 200-litre domestic hot water tank\u003c\/h2\u003e\n\n\n  \u003cp\u003e\n    The \u003cstrong\u003e200-litre domestic hot water tank\u003c\/strong\u003e is directly integrated into the indoor column. This design combines heating production and domestic hot water production in a single piece of equipment.\n  \u003c\/p\u003e\n\n\n  \u003cp\u003e\n    The system is certified for the \u003cstrong\u003eheating + domestic hot water\u003c\/strong\u003e application. The HP KEYMARK certification indicates, among other things, a domestic hot water load profile of \u003cstrong\u003eL\u003c\/strong\u003e, with a domestic hot water energy efficiency of 140% and a domestic hot water COP of 3.10 according to EN 16147.\n  \u003c\/p\u003e\n\n\n  \u003cdiv style=\"background-color: #f8f9fa; padding: 20px; margin: 25px 0;\"\u003e\n\n    \u003cp\u003e\u003cstrong\u003eDomestic hot water tank capacity:\u003c\/strong\u003e 200 L\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e heating + domestic hot water\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eSystem type:\u003c\/strong\u003e Hydro All-In-One\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eTank:\u003c\/strong\u003e integrated into the indoor unit\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eDomestic hot water draw profile:\u003c\/strong\u003e L\u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eHeating and cooling all year round\u003c\/h2\u003e\n\n\n  \u003cp\u003e\n    The Haier Hydro All-In-One R290 12 kW is a \u003cstrong\u003ereversible\u003c\/strong\u003e solution that provides heating in winter and cooling when conditions require it. The system certification confirms its reversibility.\n  \u003c\/p\u003e\n\n\n  \u003cp\u003e\n    In heating mode, the water flow temperature can reach \u003cstrong\u003e80 °C\u003c\/strong\u003e. In cooling mode, the water outlet temperature range extends from \u003cstrong\u003e5 to 25 °C\u003c\/strong\u003e.\n  \u003c\/p\u003e\n\n\n  \u003cp\u003e\n    The \u003cstrong\u003eclimate curve\u003c\/strong\u003e function automatically adapts the water temperature according to the outdoor temperature to promote comfort and energy efficiency.\n  \u003c\/p\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eA solution suitable for different heating emitters\u003c\/h2\u003e\n\n\n  \u003cp\u003e\n    The heat pump can be used with different hydraulic systems such as \u003cstrong\u003eunderfloor heating, low-temperature radiators, or certain high-temperature radiators\u003c\/strong\u003e, subject to appropriate system sizing.\n  \u003c\/p\u003e\n\n\n  \u003cp\u003e\n    The choice of water flow temperature should be made based on the emitters present in the building. The lower the required water temperature, the more favourable the operating conditions generally are for the efficiency of a heat pump.\n  \u003c\/p\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eFunctions and management options\u003c\/h2\u003e\n\n\n  \u003cul\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eClimate curve\u003c\/strong\u003e for automatic water temperature adaptation\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eTwo-zone management\u003c\/strong\u003e of heating or cooling\u003c\/li\u003e\n\n    \u003cli\u003e\u003cstrong\u003eAutomatic mode\u003c\/strong\u003e\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eSmart Grid\u003c\/strong\u003e for compatible installations\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eModbus \/ BMS communication\u003c\/strong\u003e\n\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eDomestic hot water tank management\u003c\/strong\u003e\n\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eSolar control\u003c\/strong\u003e\n\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eSwimming pool heating management\u003c\/strong\u003e depending on the configuration\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eAnti-freeze function\u003c\/strong\u003e\n\u003c\/li\u003e\n\n  \u003c\/ul\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003ePackage contents\u003c\/h2\u003e\n\n\n  \u003cdiv style=\"background-color: #f4f7f5; padding: 20px; margin: 20px 0;\"\u003e\n\n    \u003cul\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e Haier AW122HVGHA outdoor unit – 12 kW\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e Haier HU162F20AHYA indoor unit – Hydro All-In-One\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e integrated 200 L domestic hot water tank\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e buffer tank depending on the kit configuration\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e heating expansion vessel with console\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e loop circulator\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e union connection \/ hydraulic accessories\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e radio-programmable thermostat\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e electrical shut-off \/ protection device\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e set of anti-vibration mounts for the outdoor unit\u003c\/li\u003e\n\n    \u003c\/ul\u003e\n\n  \u003c\/div\u003e\n\n\n  \u003cp style=\"font-size: 13px; color: #666666;\"\u003e\n    The composition of the additional accessories depends on the commercial bundle offered. The Haier AW122HVGHA and HU162F20AHYA references make up the 12 kW single-phase Hydro All-In-One system with an integrated 200 L domestic hot water tank.\n  \u003c\/p\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eMain features\u003c\/h2\u003e\n\n\n  \u003cdiv style=\"background-color: #f8f9fa; padding: 20px; margin: 20px 0;\"\u003e\n\n    \u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Haier\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eRange:\u003c\/strong\u003e Hydro All-In-One R290\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e air\/water heat pump\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eArchitecture:\u003c\/strong\u003e Hydro All-In-One\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eNominal capacity:\u003c\/strong\u003e 12 kW\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eOutdoor unit:\u003c\/strong\u003e AW122HVGHA\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eIndoor unit:\u003c\/strong\u003e HU162F20AHYA\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eDomestic hot water tank:\u003c\/strong\u003e integrated 200 L\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R290\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003ePower supply:\u003c\/strong\u003e 220-240 V \/ 50 Hz single-phase\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eHeating capacity at A7\/W35:\u003c\/strong\u003e 12 kW\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eHeating capacity at A7\/W55:\u003c\/strong\u003e 11.5 kW\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eCOP at A7\/W35:\u003c\/strong\u003e 5.10\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eCOP at A7\/W55:\u003c\/strong\u003e 3.30\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eSCOP at 35 °C:\u003c\/strong\u003e 4.82\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eSCOP at 55 °C:\u003c\/strong\u003e 3.85\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eEnergy class:\u003c\/strong\u003e A+++ at 35 °C \/ A+++ at 55 °C\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eMaximum water outlet temperature:\u003c\/strong\u003e 80 °C\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eFunctions:\u003c\/strong\u003e heating, cooling, and domestic hot water\u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eInstallation and commissioning\u003c\/h2\u003e\n\n\n  \u003cp\u003e\n    A heat pump using \u003cstrong\u003eR290\u003c\/strong\u003e must be installed in accordance with the manufacturer's instructions and the rules applicable to equipment using this refrigerant.\n  \u003c\/p\u003e\n\n\n  \u003cp\u003e\n    The sizing of the heat pump capacity, hydraulic system, buffer tank, and emitters must be adapted to the building's thermal characteristics.\n  \u003c\/p\u003e\n\n\n  \u003cp\u003e\n    Commissioning, settings, and controls must be carried out in accordance with Haier's recommendations and current regulations by a \u003cstrong\u003equalified professional\u003c\/strong\u003e.\n  \u003c\/p\u003e\n\n\n  \u003cdiv style=\"background-color: #f4f7f5; padding: 20px; border-left: 5px solid #4d8b5b; margin-top: 25px;\"\u003e\n\n    \u003cp style=\"margin: 0;\"\u003e\n      \u003cstrong\u003eImportant:\u003c\/strong\u003e the Haier Hydro All-In-One system already incorporates its 200-litre domestic hot water tank into the HU162F20AHYA indoor unit. The exact configuration and contents of the accessory kit must be checked before installation to comply with the hydraulic diagram and the manufacturer's recommendations.\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n\n\n\u003c\/div\u003e","brand":"HAIER","offers":[{"title":"Default Title","offer_id":55289092866381,"sku":"KITCOMPHAIER12ECS","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0906\/1987\/1565\/files\/KITCOMPHAIER12ECS.png?v=1793874255","url":"https:\/\/greennegocfinds.com\/en\/products\/pompe-a-chaleur-kit-pac-air-eau-haier-hydro-all-in-one-r290-12-kw-monophasee-avec-ballon-ecs-integre-de-200-l","provider":"Green-negoce","version":"1.0","type":"link"}