{"product_id":"pompe-a-chaleur-kit-pac-air-eau-haier-r290-split-8-kw-monophasee","title":"Heat pump: Haier R290 Air\/Water Split PAC Kit 8 kW single-phase","description":"\u003cdiv style=\"font-family: Arial, Helvetica, sans-serif; color: #333333; line-height: 1.6; max-width: 1100px; margin: 0 auto;\"\u003e\n\n\n  \u003cdiv style=\"background-color: #f4f7f5; padding: 24px; border-left: 5px solid #4d8b5b; margin-bottom: 25px;\"\u003e\n\n    \u003cp style=\"font-size: 18px; margin: 0 0 10px 0;\"\u003e\n      \u003cstrong\u003eComplete Haier R290 Split 8 kW single-phase air\/water heat pump pack\u003c\/strong\u003e, with indoor hydraulic module, Atlantic Chaufféo 200 L electric water heater and accessory kit for a complete installation.\n    \u003c\/p\u003e\n\n    \u003cp style=\"margin: 0;\"\u003e\n      This two-block solution uses the \u003cstrong\u003enatural R290 refrigerant\u003c\/strong\u003e and combines energy efficiency, high water temperature and versatility to meet heating, cooling and domestic hot water production needs.\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eA complete solution for heating and domestic hot water\u003c\/h2\u003e\n\n\n  \u003cp\u003e\n    The \u003cstrong\u003eHaier R290 Split 8 kW pack\u003c\/strong\u003e is designed for renovation projects as well as new builds seeking an efficient and energy-saving heating solution.\n  \u003c\/p\u003e\n\n\n  \u003cp\u003e\n    Its \u003cstrong\u003etwo-block\u003c\/strong\u003e architecture separates the outdoor unit from the indoor hydraulic module. The heat pump recovers the calories naturally present in the outdoor air to heat the water in the heating circuit. The system can also operate in cooling mode and contribute to domestic hot water production thanks to the \u003cstrong\u003eAtlantic Chaufféo 200-litre electric water heater included in the pack\u003c\/strong\u003e.\n  \u003c\/p\u003e\n\n\n  \u003cp\u003e\n    The Haier system uses \u003cstrong\u003eR290\u003c\/strong\u003e, a natural refrigerant with a very low global warming potential, and benefits from Inverter technology allowing the operating power to be adapted to the building's needs.\n  \u003c\/p\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eThe highlights of the Haier R290 8 kW pack\u003c\/h2\u003e\n\n\n  \u003cul\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003e8 kW nominal heating power\u003c\/strong\u003e\n\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eSplit two-block technology\u003c\/strong\u003e with separate outdoor unit and indoor hydraulic module\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eR290 refrigerant\u003c\/strong\u003e, natural and with low environmental impact\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eEnergy class A+++\u003c\/strong\u003e for heating at 35 °C and 55 °C\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eCOP up to 5.18\u003c\/strong\u003e depending on operating conditions\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eSCOP up to 5.25\u003c\/strong\u003e at low temperature according to manufacturer data\u003c\/li\u003e\n\n    \u003cli\u003eHeating and \u003cstrong\u003ecooling\u003c\/strong\u003e operation\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eWater flow temperature up to 85 °C\u003c\/strong\u003e depending on conditions and operating mode\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eHeating operation down to -30 °C outdoor temperature\u003c\/strong\u003e\n\n\u003c\/li\u003e\n\n    \u003cli\u003e\u003cstrong\u003e220-240 V \/ 50 Hz single-phase power supply\u003c\/strong\u003e\u003c\/li\u003e\n\n    \u003cli\u003eHydraulic module equipped with an \u003cstrong\u003e8-litre expansion vessel\u003c\/strong\u003e\n\n\u003c\/li\u003e\n\n    \u003cli\u003eIntegrated \u003cstrong\u003e3 kW\u003c\/strong\u003e electric auxiliary heater\n\n\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eAtlantic Chaufféo 200 L domestic hot water tank\u003c\/strong\u003e included\u003c\/li\u003e\n\n    \u003cli\u003eAccessory kit including buffer tank, expansion vessel, circulator, thermostat and safety devices\u003c\/li\u003e\n\n  \u003c\/ul\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eA heat pump suited for renovation\u003c\/h2\u003e\n\n\n  \u003cp\u003e\n    Thanks to its ability to produce high-temperature heating water, the \u003cstrong\u003eHaier R290 Split 8 kW heat pump\u003c\/strong\u003e can be integrated into various residential projects, particularly when replacing an old heating system.\n  \u003c\/p\u003e\n\n\n  \u003cp\u003e\n    It can notably be combined with \u003cstrong\u003ewater radiators\u003c\/strong\u003e or low-temperature heating systems such as underfloor heating, subject to the sizing and hydraulic configuration of the installation.\n  \u003c\/p\u003e\n\n\n  \u003cp\u003e\n    Inverter technology allows the heat pump to adjust its operation according to needs, promoting more stable operation and better control of electricity consumption.\n  \u003c\/p\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eR290 technology: performance and energy transition\u003c\/h2\u003e\n\n\n  \u003cp\u003e\n    \u003cstrong\u003eR290 (propane)\u003c\/strong\u003e is a natural refrigerant used in new generations of heat pumps. Its very low global warming potential makes it a particularly interesting solution in the context of evolving European regulations on refrigerants.\n  \u003c\/p\u003e\n\n\n  \u003cp\u003e\n    Combined with Inverter technology and optimized operation at different water temperatures, the Haier system allows for a good compromise between \u003cstrong\u003ethermal comfort, energy efficiency and consumption control\u003c\/strong\u003e.\n  \u003c\/p\u003e\n\n\n  \u003cdiv style=\"background-color: #f8f9fa; padding: 20px; margin: 25px 0;\"\u003e\n\n    \u003ch2 style=\"color: #2f6f3e; margin-top: 0;\"\u003eTechnical performance\u003c\/h2\u003e\n\n\n    \u003cp\u003e\u003cstrong\u003eHeating power at 7 °C outdoor \/ 35 °C water:\u003c\/strong\u003e 8 kW\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003ePower consumption at 7 °C \/ 35 °C water:\u003c\/strong\u003e approximately 1.62 kW\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eCOP at 7 °C \/ 35 °C water:\u003c\/strong\u003e up to 5.18 according to manufacturer data\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eHeating power at 7 °C outdoor \/ 55 °C water:\u003c\/strong\u003e 8 kW\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003ePower consumption at 7 °C \/ 55 °C water:\u003c\/strong\u003e approximately 2.35 kW\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eCOP at 7 °C \/ 55 °C water:\u003c\/strong\u003e up to 3.54 depending on measurement conditions\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eSCOP at 35 °C:\u003c\/strong\u003e up to 5.25\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eSCOP at 55 °C:\u003c\/strong\u003e up to 4.17\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eEnergy class:\u003c\/strong\u003e A+++ at 35 °C \/ A+++ at 55 °C\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R290\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003ePower supply:\u003c\/strong\u003e 220-240 V \/ 50 Hz single-phase\u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n\n  \u003cp style=\"font-size: 13px; color: #666666;\"\u003e\n    COP and SCOP performance vary depending on outdoor and water temperature conditions. The indicated values correspond to the manufacturer's measurement conditions and do not constitute a fixed electricity consumption.\n  \u003c\/p\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eHaier HPM08-ND2-H outdoor unit\u003c\/h2\u003e\n\n\n  \u003cp\u003e\n    The \u003cstrong\u003eHPM08-ND2-H\u003c\/strong\u003e outdoor unit forms the thermodynamic heart of the system. It recovers calories from the outdoor air and transfers them to the hydraulic circuit via the indoor module.\n  \u003c\/p\u003e\n\n\n  \u003cul\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eModel:\u003c\/strong\u003e HPM08-ND2-H\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eNominal heating power:\u003c\/strong\u003e 8 kW\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e 220-240 V \/ 50 Hz single-phase\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R290\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eCompressor:\u003c\/strong\u003e DC Inverter technology\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eHeating operating range:\u003c\/strong\u003e approximately -30 to +35 °C\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eCooling operating range:\u003c\/strong\u003e approximately 10 to +50 °C\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eHeating water temperature:\u003c\/strong\u003e up to 85 °C depending on operating conditions\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eIndicative dimensions:\u003c\/strong\u003e 1272 × 534 × 822 mm\u003c\/li\u003e\n\n  \u003c\/ul\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eHaier HPM06(12)-ND2-WW1 indoor hydraulic module\u003c\/h2\u003e\n\n\n  \u003cp\u003e\n    The \u003cstrong\u003eHPM06(12)-ND2-WW1\u003c\/strong\u003e indoor hydraulic module groups the main hydraulic and control elements required for the heat pump's operation. Its power range allows it to be combined with different outdoor units in the range.\n  \u003c\/p\u003e\n\n\n  \u003cul\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eModel:\u003c\/strong\u003e HPM06(12)-ND2-WW1\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e 220-240 V \/ 50 Hz\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eIntegrated expansion vessel:\u003c\/strong\u003e 8 L\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eElectric auxiliary heater:\u003c\/strong\u003e 3 kW\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003ePump maximum head:\u003c\/strong\u003e approximately 9 m\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e TFT screen\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e approximately 500 × 887 × 309 mm\u003c\/li\u003e\n\n  \u003c\/ul\u003e\n\n\n  \u003cp\u003e\n    The hydraulic module ensures the circulation of water and the management of the installation's various operating parameters. It is connected to the outdoor unit by the Split system's refrigeration circuit and by the connections necessary for control.\n  \u003c\/p\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eAtlantic Chaufféo 200 L electric water heater\u003c\/h2\u003e\n\n\n  \u003cp\u003e\n    The pack also includes an \u003cstrong\u003eAtlantic Chaufféo 200-litre electric water heater\u003c\/strong\u003e intended to ensure the production of domestic hot water for the home.\n  \u003c\/p\u003e\n\n\n  \u003cp\u003e\n    It is a \u003cstrong\u003edomestic hot water tank separate from the heat pump\u003c\/strong\u003e. This configuration provides a complete solution combining heat pump heating and domestic hot water production.\n  \u003c\/p\u003e\n\n\n  \u003cdiv style=\"background-color: #f4f7f5; padding: 20px; margin: 25px 0;\"\u003e\n\n    \u003ch2 style=\"color: #2f6f3e; margin-top: 0;\"\u003ePack contents\u003c\/h2\u003e\n\n\n    \u003cul\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e Haier HPM06(12)-ND2-WW1 indoor unit\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e Haier HPM08-ND2-H outdoor unit – 8 kW\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e magnetic sludge trap with Ø1\" shut-off valves\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e Ø3\/4\" FF CA573 disconnecter\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e Rubber Foot anti-vibration support\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e Ecoya P.110.88 PWM Ø1\"1\/2 male circulator\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e Ø1\" F × 1\"1\/2 circulator union fitting\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e 25 L heating expansion vessel\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e console equipped for heating expansion vessel\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e T3R programmable wireless radio thermostat\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e emergency button with 4P 32A single\/three-phase disconnect switch\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e 50 L buffer tank with 4 connections\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003e2 ×\u003c\/strong\u003e 1\" male anti-freeze valves\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e Atlantic Chaufféo 200 L electric water heater\u003c\/li\u003e\n\n    \u003c\/ul\u003e\n\n  \u003c\/div\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003e50 L buffer tank included\u003c\/h2\u003e\n\n\n  \u003cp\u003e\n    The \u003cstrong\u003e50-litre buffer tank\u003c\/strong\u003e included in the kit helps improve the hydraulic stability of the installation and promotes the proper operation of the heating circuit.\n  \u003c\/p\u003e\n\n\n  \u003cp\u003e\n    Its inclusion in the pack simplifies the assembly of the installation by grouping several elements required for the hydraulic installation.\n  \u003c\/p\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eAn accessory kit designed for a complete installation\u003c\/h2\u003e\n\n\n  \u003cp\u003e\n    The pack is not limited to the heat pump and the domestic hot water tank. It also includes several hydraulic, electrical and control components allowing you to have a complete base for the installation.\n  \u003c\/p\u003e\n\n\n  \u003cul\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eHydraulic protection:\u003c\/strong\u003e magnetic sludge trap and disconnecter\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eHydraulic stability:\u003c\/strong\u003e 50 L buffer tank\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eExpansion:\u003c\/strong\u003e 25 L heating expansion vessel with console\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eCirculation:\u003c\/strong\u003e PWM circulator\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eControl:\u003c\/strong\u003e T3R programmable radio thermostat\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eElectrical protection:\u003c\/strong\u003e emergency disconnect switch\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eFreeze protection:\u003c\/strong\u003e two anti-freeze valves\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eOutdoor installation:\u003c\/strong\u003e Rubber Foot anti-vibration supports\u003c\/li\u003e\n\n  \u003c\/ul\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eMain features\u003c\/h2\u003e\n\n\n  \u003cdiv style=\"background-color: #f8f9fa; padding: 20px; margin: 20px 0;\"\u003e\n\n    \u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Haier\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eRange:\u003c\/strong\u003e R290 Split\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e Two-block air\/water heat pump\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e 8 kW\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003ePower supply:\u003c\/strong\u003e 220-240 V \/ 50 Hz single-phase\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R290\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eEnergy class:\u003c\/strong\u003e A+++ at 35 °C \/ A+++ at 55 °C\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eMaximum water temperature:\u003c\/strong\u003e up to 85 °C depending on operating conditions\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eFunctions:\u003c\/strong\u003e heating, cooling and domestic hot water production via the dedicated tank\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eDomestic hot water tank:\u003c\/strong\u003e Atlantic Chaufféo 200 L\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eBuffer tank:\u003c\/strong\u003e 50 L\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eElectric auxiliary heater:\u003c\/strong\u003e 3 kW\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eExpansion vessel integrated into the hydraulic module:\u003c\/strong\u003e 8 L\u003c\/p\u003e\n\n    \u003cp\u003e\u003cstrong\u003eHeating expansion vessel included in the kit:\u003c\/strong\u003e 25 L\u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eInstallation and commissioning\u003c\/h2\u003e\n\n\n  \u003cp\u003e\n    A heat pump using \u003cstrong\u003eR290\u003c\/strong\u003e must be installed in accordance with the manufacturer's specifications and the rules applicable to installations using this refrigerant.\n  \u003c\/p\u003e\n\n\n  \u003cp\u003e\n    The sizing of the heat pump, buffer tank, heating emitters and hydraulic network must be carried out according to the characteristics of the home and the thermal needs.\n  \u003c\/p\u003e\n\n\n  \u003cp\u003e\n    The commissioning and controls of the installation must be carried out by a \u003cstrong\u003equalified professional\u003c\/strong\u003e, in accordance with Haier's recommendations and current regulations.\n  \u003c\/p\u003e\n\n\n  \u003cdiv style=\"background-color: #f4f7f5; padding: 20px; border-left: 5px solid #4d8b5b; margin-top: 25px;\"\u003e\n\n    \u003cp style=\"margin: 0;\"\u003e\n      \u003cstrong\u003eImportant:\u003c\/strong\u003e the pack includes several distinct pieces of equipment. The Haier indoor hydraulic module, the Haier outdoor unit, the buffer tank and the Atlantic Chaufféo 200 L water heater are separate elements that must be installed and connected in accordance with the hydraulic diagram and the manufacturers' recommendations.\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n\n\n\u003c\/div\u003e","brand":"HAIER","offers":[{"title":"Default Title","offer_id":55288996331853,"sku":"KITCOMPHAIER8HYDRO","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0906\/1987\/1565\/files\/KITCOMPHAIER8HYDRO.png?v=1793873168","url":"https:\/\/greennegocfinds.com\/en\/products\/pompe-a-chaleur-kit-pac-air-eau-haier-r290-split-8-kw-monophasee","provider":"Green-negoce","version":"1.0","type":"link"}