{"product_id":"pompe-a-chaleur-kit-pac-air-eau-monobloc-r290-16-kw-monophasee-avec-chauffe-eau-200-l-et-kit-accessoires","title":"Heat pump: Haier Monobloc R290 16 kW single-phase air\/water PAC kit with 200 L water heater and accessory kit","description":"\u003cdiv style=\"font-family: Arial, Helvetica, sans-serif; color: #333333; line-height: 1.6; max-width: 1100px; margin: 0 auto;\"\u003e\n\n\n  \u003cdiv style=\"background-color: #f4f7f5; padding: 24px; border-left: 5px solid #4d8b5b; margin-bottom: 25px;\"\u003e\n\n    \u003ch2 style=\"color: #2f6f3e; margin-top: 0;\"\u003eComplete Haier Monobloc R290 16 kW single-phase air\/water heat pump pack with 200 L water heater and accessory kit\u003c\/h2\u003e\n\n    \u003cp style=\"margin-bottom: 0;\"\u003e\n      The \u003cstrong\u003ecomplete Haier Monobloc R290 16 kW single-phase pack\u003c\/strong\u003e is a high-power air\/water heating solution designed particularly for large homes or those with significant thermal requirements. It combines a \u003cstrong\u003e16 kW Haier Monobloc R290 heat pump\u003c\/strong\u003e, an \u003cstrong\u003eAtlantic Chaufféo 200 L\u003c\/strong\u003e electric water heater, and a set of accessories required to complete the hydraulic installation.\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eA complete heating and domestic hot water solution\u003c\/h2\u003e\n\n\n  \u003cp\u003e\n    The \u003cstrong\u003eHaier AW162MXGHA\u003c\/strong\u003e heat pump belongs to the Haier Monobloc GT R290 range. With its nominal power of \u003cstrong\u003e16 kW\u003c\/strong\u003e and 230 V single-phase power supply, it is an ideal solution for renovation projects or the replacement of an existing heating system requiring high power.\n  \u003c\/p\u003e\n\n\n  \u003cp\u003e\n    This air\/water heat pump uses the \u003cstrong\u003enatural R290 refrigerant\u003c\/strong\u003e and Inverter technology, allowing the compressor's operation to adapt to heating requirements. The monobloc design houses the refrigeration circuit in the outdoor unit and simplifies connection to the building's hydraulic system.\n  \u003c\/p\u003e\n\n\n  \u003cdiv style=\"background-color: #f8f9fa; padding: 20px; margin: 25px 0;\"\u003e\n\n    \u003ch2 style=\"color: #2f6f3e; margin-top: 0;\"\u003eHaier 16 kW heat pump performance\u003c\/h2\u003e\n\n\n    \u003cul\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003eNominal heating power:\u003c\/strong\u003e 16 kW at 7 °C outdoor \/ 35 °C water\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003eHeating power:\u003c\/strong\u003e 15.5 kW at 7 °C outdoor \/ 55 °C water\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003eElectrical power input:\u003c\/strong\u003e 3.23 kW at 7 °C \/ 35 °C water\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003eElectrical power input:\u003c\/strong\u003e 5.08 kW at 7 °C \/ 55 °C water\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003eCOP:\u003c\/strong\u003e 4.95 at 7 °C \/ 35 °C water\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003eCOP:\u003c\/strong\u003e 3.05 at 7 °C \/ 55 °C water\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003eEnergy class:\u003c\/strong\u003e A+++ \/ A+++ depending on the configuration and operating conditions\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R290\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e 230 V \/ 50 Hz single-phase\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003eMaximum water temperature:\u003c\/strong\u003e up to approximately 80 °C depending on operating conditions\u003c\/li\u003e\n\n    \u003c\/ul\u003e\n\n\n    \u003cp style=\"margin-bottom: 0;\"\u003e\n      The performance values shown above are from the Haier technical documentation for the \u003cstrong\u003eAW162MXGHA\u003c\/strong\u003e model.\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eHaier R290 Monobloc technology\u003c\/h2\u003e\n\n\n  \u003cp\u003e\n    The \u003cstrong\u003eMonobloc GT R290\u003c\/strong\u003e technology includes a water pump, expansion vessel, and flow meter directly in the unit. Haier also includes a wiring center to simplify the electrical connection of the installation.\n  \u003c\/p\u003e\n\n\n  \u003cp\u003e\n    The range offers various management and control functions, including \u003cstrong\u003etwo-zone heating management\u003c\/strong\u003e, weather compensation, automatic mode, Smart Grid function, Modbus communication, domestic hot water tank management, solar control, pool heating, and frost protection.\n  \u003c\/p\u003e\n\n\n  \u003cdiv style=\"background-color: #f4f7f5; padding: 20px; margin: 25px 0;\"\u003e\n\n    \u003ch2 style=\"color: #2f6f3e; margin-top: 0;\"\u003eAtlantic Chaufféo 200 L electric water heater\u003c\/h2\u003e\n\n\n    \u003cp\u003e\n      The pack includes an \u003cstrong\u003eAtlantic Chaufféo 200-liter electric water heater\u003c\/strong\u003e designed to store domestic hot water.\n    \u003c\/p\u003e\n\n\n    \u003cp style=\"margin-bottom: 0;\"\u003e\n      Combining the Haier heat pump with this tank provides a comprehensive solution for \u003cstrong\u003ehome heating and domestic hot water production\u003c\/strong\u003e.\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eKit contents\u003c\/h2\u003e\n\n\n  \u003cp\u003e\n    The pack includes the heat pump, the electric water heater, and a set of hydraulic, control, and safety accessories.\n  \u003c\/p\u003e\n\n\n  \u003cul\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e Haier Monobloc R290 16 kW single-phase air\/water heat pump\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e Magnetic sludge trap with shut-off valves Ø 1\"\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e Ø 3\/4\" FF CA573 disconnecter\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e Rubber Foot anti-vibration mount\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e Ecoya P.110.88 PWM circulator Ø 1\"1\/2 male\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e Ø 1\" F × 1\"1\/2 union fitting for circulator\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e 18 L heating expansion vessel\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e Heating expansion vessel control panel\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e T3R programmable wireless radio thermostat\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e Emergency button with 4P 32A single\/three-phase disconnect switch\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003e2 ×\u003c\/strong\u003e Ø 1\" male anti-freeze valve\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003e1 ×\u003c\/strong\u003e Atlantic Chaufféo 200 L electric water heater\u003c\/li\u003e\n\n  \u003c\/ul\u003e\n\n\n  \u003cdiv style=\"background-color: #f8f9fa; padding: 20px; margin: 25px 0;\"\u003e\n\n    \u003ch2 style=\"color: #2f6f3e; margin-top: 0;\"\u003eBuffer tank\u003c\/h2\u003e\n\n\n    \u003cp\u003e\n      The kit configuration also includes the integration of a \u003cstrong\u003ebuffer tank\u003c\/strong\u003e. The volume should be selected to suit the hydraulic configuration of the installation, the heat pump sizing, and the project requirements.\n    \u003c\/p\u003e\n\n\n    \u003cp style=\"margin-bottom: 0;\"\u003e\n      The buffer tank, among other things, increases the volume of water available in the circuit and helps optimize the hydraulic operation of the installation.\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eMain technical specifications\u003c\/h2\u003e\n\n\n  \u003cdiv style=\"background-color: #f8f9fa; padding: 20px; margin: 25px 0;\"\u003e\n\n    \u003cul\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Haier\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003eRange:\u003c\/strong\u003e HPM R290 \/ Monobloc GT R290\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003eHeat pump model:\u003c\/strong\u003e AW162MXGHA\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003eType:\u003c\/strong\u003e monobloc air\/water heat pump\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003eNominal power:\u003c\/strong\u003e 16 kW\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e 230 V \/ 50 Hz single-phase\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R290\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003eEnergy class:\u003c\/strong\u003e A+++ \/ A+++\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003eNet outdoor unit dimensions:\u003c\/strong\u003e 1380 × 880 × 460 mm (L × H × D)\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003eNet outdoor unit weight:\u003c\/strong\u003e approximately 136 kg\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003eSound pressure level:\u003c\/strong\u003e approximately 55 dB(A)\u003c\/li\u003e\n\n      \u003cli\u003e\n\n\u003cstrong\u003eSound power level:\u003c\/strong\u003e approximately 66 dB(A)\u003c\/li\u003e\n\n    \u003c\/ul\u003e\n\n\n    \u003cp style=\"margin-bottom: 0;\"\u003e\n      The dimensions, weight, and sound levels are from the Haier technical documentation for the 16 kW single-phase version.\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n\n  \u003ch2 style=\"color: #2f6f3e;\"\u003eBenefits of the Haier 16 kW pack\u003c\/h2\u003e\n\n\n  \u003cul\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003e16 kW of power\u003c\/strong\u003e to meet the needs of large heating installations.\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eMonobloc technology\u003c\/strong\u003e with the refrigeration circuit integrated in the outdoor unit.\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eNatural R290 refrigerant\u003c\/strong\u003e with low global warming potential.\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eInverter technology\u003c\/strong\u003e to adapt the heat pump's operation to thermal requirements.\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eHigh flow temperature\u003c\/strong\u003e allowing for the renovation of certain existing installations.\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eEnergy class A+++\u003c\/strong\u003e according to the operating conditions defined by the manufacturer.\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eAtlantic Chaufféo 200 L water heater\u003c\/strong\u003e included for domestic hot water production.\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003eHydraulic and safety accessories\u003c\/strong\u003e included to simplify the installation.\u003c\/li\u003e\n\n    \u003cli\u003e\n\n\u003cstrong\u003e230 V single-phase power supply\u003c\/strong\u003e, suitable for installations with a single-phase electrical supply.\u003c\/li\u003e\n\n  \u003c\/ul\u003e\n\n\n  \u003cdiv style=\"background-color: #f4f7f5; padding: 20px; border-left: 5px solid #4d8b5b; margin-top: 30px;\"\u003e\n\n    \u003ch2 style=\"color: #2f6f3e; margin-top: 0;\"\u003eInstallation and commissioning\u003c\/h2\u003e\n\n\n    \u003cp\u003e\n      A 16 kW air\/water heat pump must be sized according to the building's heat losses, the reference outdoor temperature, the type of heating emitters, and the required water temperature.\n    \u003c\/p\u003e\n\n\n    \u003cp\u003e\n      Before placing an order, it is recommended to check that the \u003cstrong\u003e16 kW\u003c\/strong\u003e power is compatible with the home's actual requirements, as well as the configuration of the hydraulic system, electrical supply, and domestic hot water production.\n    \u003c\/p\u003e\n\n\n    \u003cp\u003e\n      The installation, hydraulic connection, electrical connection, settings, and commissioning must be carried out by a qualified professional in accordance with the manufacturer's instructions and applicable technical regulations.\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n\n  \u003cdiv style=\"background-color: #f8f9fa; padding: 20px; margin-top: 25px;\"\u003e\n\n    \u003ch2 style=\"color: #2f6f3e; margin-top: 0;\"\u003eKey points\u003c\/h2\u003e\n\n\n    \u003cp\u003e\n      The \u003cstrong\u003ecomplete Haier Monobloc R290 16 kW single-phase heat pump pack\u003c\/strong\u003e is a high-power solution designed for air\/water heating projects requiring significant thermal capacity. It combines the Haier AW162MXGHA heat pump, an Atlantic Chaufféo 200 L electric water heater, and a set of hydraulic, control, and safety accessories.\n    \u003c\/p\u003e\n\n\n    \u003cp style=\"margin-bottom: 0;\"\u003e\n      \u003cstrong\u003eProduct reference: KITCOMPHAIER16\u003c\/strong\u003e\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n\n\n\u003c\/div\u003e","brand":"HAIER","offers":[{"title":"Default Title","offer_id":55288575000909,"sku":"KITCOMPHAIER16","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0906\/1987\/1565\/files\/KITCOMPHAIER16.png?v=1793870345","url":"https:\/\/greennegocfinds.com\/en\/products\/pompe-a-chaleur-kit-pac-air-eau-monobloc-r290-16-kw-monophasee-avec-chauffe-eau-200-l-et-kit-accessoires","provider":"Green-negoce","version":"1.0","type":"link"}